Before first use
Children must not play with the appliance; supervise children's cleaning. If the cord, adapter or appliance is damaged, stop using it and contact Philips. This appliance does not replace ventilation or a carbon-monoxide safety device.
Use a dry, level surface with at least 20 cm clear around the appliance and 30 cm above it. Keep air openings clear and the surrounding area dry.
With the appliance unplugged, remove the front cover and water tank. Remove all packaging from the FY3400 purification filter and FY3401 humidification filter. Fit the bracket around the humidification filter, then refit both filters, the cover and tank.
Use the supplied adapter only. Connect it to the appliance first, then the wall socket.
Switch off and unplug before cleaning, filling, moving or replacing filters. Use no abrasive, aggressive or flammable cleaners. Never put liquid on the purification filter or vacuum the particle sensor. Keep water out of the air openings and nearby sockets dry. Keep the appliance upright while cleaning.
Weekly
Take the humidification filter out of the water tank.
Add water and a little mild washing-up liquid. Wipe the inside with a soft, clean cloth, then empty the tank into a sink.
Put the humidification filter back in the tank.
Weekly
Pull out the tank and lift the bracket away from the FY3401 humidification filter.
Mix 24 g citric acid with 4 litres of water in a container. Soak the filter for 1 hour.
Rinse under a slowly running tap. Do not squeeze or wring the filter, or put it in a dishwasher or washing machine.
Fit the bracket correctly around the filter, return it to the tank and slide the tank back into the appliance. Wash your hands thoroughly.
Every 2 months
Every 2 months, or sooner: Sooner in dusty or very humid conditions
Clean more often in dusty surroundings. High humidity can leave condensation on the sensor and cause an incorrect poor-air-quality reading; clean it if this happens.
Open the air-quality sensor cover.
Clean the particle sensor with a damp cotton swab, then dry all parts thoroughly with a dry cotton swab.
Close the sensor cover.
Every 6 months
Philips recommends replacement every 6 months for optimal performance. A filter still in good condition may last longer, but replace it at least once a year. Replace a very dirty filter with dark spots before using the appliance again after a long break.
Pull out the water tank. Remove the bracket from the FY3401 filter and discard the used filter.
Unpack an original Philips FY3401 humidification filter. Fit the bracket correctly around it and return the tank to the appliance.
Wash your hands thoroughly.
When the water light stays orange
Pull out the water tank and slowly add cold tap water, watching the level window. Stay below the maximum mark. Do not add fragrance, chemicals, hot water or groundwater.
Place the tank back correctly. A flashing orange humidification light means the tank needs to be seated correctly; a steady orange light means it needs water.
When the filter-cleaning alert appears
Pull off the front cover and take out the purification filter.
Use a vacuum cleaner on the filter's surface. Never wash it.
Refit the filter and front cover, reconnect the adapter and press the power button.
Hold the light-function and mode buttons together for 3 seconds. The cleaning alert disappears when the reset succeeds. You can also reset the cleaning time in the Air+ app.
Wash your hands thoroughly after handling the filter.
When the replacement alert turns red
Replace promptly when the red alert appears. If left unchanged, the appliance can lock and stop working. Reset only after actually replacing the filter.
Remove the front cover, take out the used FY3400 filter and discard it. Remove all packaging from a new original Philips FY3400 filter, fit it and refit the cover. Do not wash, reuse or smell the used filter.
Reconnect the adapter and press power. Hold the light-function and mode buttons together for 3 seconds, or reset the filter lifetime in the Air+ app. Check that the replacement alert disappears.
After fitting the new filter, switch off and unplug. Wait at least 10 seconds before reconnecting. Within 15 seconds after powering on, hold the light-function and mode buttons together for 3 seconds to reset the lifetime counter.
Wash your hands thoroughly after handling the filters.
When dust collects
Wipe the inside and outside plastic surfaces and the air outlet with a soft, dry cloth.
Before storing the appliance
Do not leave water in the reservoir while the appliance is unused. Clean the tank, humidification filter, appliance and purification-filter surface using their care guides.
Let all parts air-dry thoroughly. Wrap the filters in airtight plastic bags and store the appliance and filters somewhere cool and dry. Wash your hands after handling filters.
Clean the appliance before using it again. Check the humidification filter; replace it if it is very dirty with dark spots.