Coffee machine
Clear care instructions, helpful schedules and manuals, all in one calm place.
Your own reminders, documents and care history. Add it once. We’ll take care of the rest.
Daily
Remove and empty the drip tray daily, or sooner if the red full-tray indicator rises above it.
Weekly
Switch off the machine. Remove the water reservoir and open the service door. Press PUSH and pull the brew-group handle to remove the brew group.
Rinse the brew group thoroughly under the tap, carefully cleaning its upper filter. Let it air-dry; do not dry it with a cloth.
Align the arrow on the yellow circle with the black arrow and N; if needed, lower the lever until it touches the bottom of the brew group. Slide the brew group along its rails until it clicks, without pressing PUSH. Close the service door and refit the water reservoir.
Weekly
Check the pre-ground-coffee compartment for blockage each week.
Unplug the machine and remove the brew group. Open the compartment lid and insert the handle of a spoon. Move the handle up and down until the compacted coffee falls down.
Weekly
Remove the container while the machine is on. Rinse it under the tap with a little washing-up liquid, or clean it in the dishwasher.
Weekly
Remove the drip tray and rinse it under the tap with a little washing-up liquid, or clean it in the dishwasher.
Weekly
Rinse the water reservoir under the tap.
Weekly
Clean the front of the machine with a soft cloth.
Monthly
Use only Philips coffee-oil-removal tablets for this cleaning procedure.
Tap Clean, use the arrows to select 'Zetgroep reinigen', and press OK. Follow the on-screen instructions.
Every 2 months
Switch off the machine, remove the water reservoir and open the service door. Press PUSH and pull the brew group out by its handle.
Apply a thin layer to the piston (grey area), the shaft beneath the group (yellow area), and the guide rails on both sides.
Check that the arrow on the yellow circle at the side of the brew group is aligned with the black arrow and N. Slide the brew group along the side guide rails back into the machine until it clicks. Do not press the PUSH button. Close the service door and refit the water reservoir.
Every 3 months
Replace the filter at least every three months, or sooner when the filter reaches 0% or the machine asks. Replace it after more than 95 litres of water have passed through it. Remove the old filter. If the filter-status light has disappeared, descale the machine before fitting and activating a replacement.
Tap Clean, select AquaClean with the arrows, and press OK. Press OK again when the activation screen appears and follow the display instructions.
Shake the filter for about 5 seconds. Immerse it upside down in a bowl of cold water and shake and press it.
Place it vertically on the filter base in the water reservoir and press it fully down. Fill the reservoir with fresh water and refit it.
Remove LatteGo if attached and place a bowl under the hot-water spout. Press start/stop. The machine dispenses hot water for one minute to activate the filter.
After each use
With LatteGo correctly attached, place a cup under its spout. Tap Clean, select 'Quick milk clean', press OK and follow the display instructions.
For washing, remove LatteGo and discard any remaining milk. Press the release button and separate the milk container from its frame. Wash the parts in the dishwasher or under the tap with lukewarm water and washing-up liquid.
When the machine asks you to empty the coffee grounds container
Remove and empty the grounds container while the machine is switched on. Wait 5 seconds before putting it back.
When the machine displays a descaling message
Tap Clean and select 'Ontkalken'. Follow the display instructions. Remove LatteGo, then remove, empty and refit the drip tray and grounds container.
Remove and empty the water reservoir, then remove the AquaClean filter. Pour in the entire bottle of Philips descaler and add water to the Calc/Clean mark. Refit the reservoir.
Place a 1.5-litre bowl under the coffee and hot-water spouts. Press start/stop. Let the approximately 30-minute descaling and rinsing cycles finish; refill the reservoir when the display requests it.
When the machine stops dispensing and the procedure is complete, install and activate a new AquaClean filter.
Empty and thoroughly rinse the reservoir. Fill it with clean water to Calc/Clean and switch the machine on. Before preparing a drink, dispense half a reservoir of hot water, then prepare two pre-ground coffees without adding coffee. Repeat the incomplete descaling procedure as soon as possible.